Red Alert® Type MC-FPLP Fire Alarm and Control 600V THHN/THWN
Home / Cables and electrical materials / UL/CSA Cables / Red Alert® Type MC-FPLP Fire Alarm and Control 600V THHN/THWN
Red Alert® Type MC-FPLP Fire Alarm and Control 600V THHN/THWN

Description:
Red Alert® Type MC - FPLP Cable is constructed with soft-drawn copper conductors and insulated with flame-retardant and heat-resistant PVC with an outer oil- and gasoline-resistant nylon jacket. Type THHN/THWN conductors are provided for sizes 14 AWG and 12 AWG cables; Type TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The circuit conductors and a green insulated grounding conductor are cabled together and a polypropylene
tape is wrapped around the assembly. Upon request, an optional Film/Foil Aluminum Laminate Shielding Tape with a tinned copper drain wire/grounding conductor is wrapped over the conductor assembly. Aluminum interlocking armor Red in color is applied over the assembly. Multiple twisted (cabled) conductor pairs/groups with optional shield(s) are available. The cable is dual rated as 90°C dry, 600 Volt Type MC and 105°C dry, 300 Volt Type FPLP cable.

Standards:
• UL 83
• UL 1063
• UL 1569
• UL 1424
• UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
• NFPA 262-2002 Standard Method of Test For Flame and Smoke of Wire and Cables for Use in AirHandling Spaces
• Federal Specification A-A59544 (formerly J-C-30B)
• IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
• NFPA 70 (National Electrical Code), Article 330
• Approved for the State of Rhode Island Fire Systems
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
• REACH/RoHS-2 (Chemical Limit) Compliant

Application:
• Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).
• Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices
• Class 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.
• Power, lighting, control, and signal circuits.
• Fished or embedded in plaster
• Concealed or exposed installations.
• Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.
• Installation in cable tray and approved raceways.
• Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).


Conductors
Ground wire
Stock
number
No. of
conductors
Size
(mm2)
No. of
strands
Insulation
thickness (mm)
Size
(AWG)
Nom.
OD(mm)
Nominal Total
Weight (kgs/km)
554549 2 18 AWG 1 0.38 18 9.43 84
677747 2 18 AWG 1 0.38 18 9.56 86
554687 4 18 AWG 1 0.38 18 10.66 115
553124 6 18 AWG 1 0.38 18 11.65 141
554551 2 16 AWG 1 0.38 16 10.59 107
554689 4 16 AWG 1 0.38 16 11.38 144
553128 6 16 AWG 1 0.38 16 12.46 182
641527 8 16 AWG 1 0.38 16 13.63 205
554537 2 14 AWG 1 0.38 14 10.98 135
559605 3 14 AWG 19 0.38 14 12.15 170
554539 4 14 AWG 1 0.38 14 12.43 191
554969 5 14 AWG 19 0.38 12 16.94 236
561684 6 14 AWG 1 0.38 14 13.72 248
554540 2 12 AWG 1 0.38 12 11.79 175
554541 4 12 AWG 1 0.38 12 13.48 259
583397 4 10 AWG 19 0.51 10 17.24 410
590897 6 10 AWG 19 0.51 10 19.80 753
647335 16 10 AWG 19 0.51 10 25.98 1144
598028 4 12 AWG 0 0.38 12 17.96 355
555576 4 12 AWG 1 0.38 12 17.38 269
596502 6 12 AWG 1 0.38 12 18.67 334
641287 4 12 AWG 1 0.38 12 16.77 245
587151 4 14/14 AWG 1 0.38 14 17.56 262
599561 4 14 AWG 1 0.38 16 16.46 222
554545 4 14 AWG 1 0.38 14 15.57 202
553161 4 14 AWG 1 0.38 12 15.53 191
599130 4 14 AWG 1 0.38 12 15.53 255
585167 4 14 AWG 1 0.38 16 19.59 335
679360 4 14 AWG 1 0.38 18 16.32 210
677915 6 18 AWG 1 0.38 14 19.58 375
640707 2 18 AWG 16 0.38 18 10.20 91
Consent to the processing of personal data ⨯

When processing your personal data, it complies with the laws and regulations applicable in Bulgaria in connection with the protection of personal data, including, but not limited to, Regulation (EU) 2016/679 ("the Regulation").

When you visit our site, we receive and store information about this visit (date, time and IP address), and in view of the normal functioning of the site, we collect the following Cookies for functionalities and preferences:

Google Analytics

An online web analytics platform from Google Inc. Google Analytics generates cookies, which are stored on your hard drive in order to analyze your actions on the website and all information that the cookie collects for you as an online user is sent for analysis to a Google server in the United States.

All user data collected through the use of cookies is anonymous and is used solely for marketing purposes, to analyze user behavior, to optimize and improve the content of the website and to determine the preferences and interests of users.

Please get acquainted and make your choice!

When processing personal data, Kabelmet complies with the laws and regulations applicable in Bulgaria in relation to the protection of personal data, including, but not limited to, Regulation (EU) 2016/679 ("the Regulation"). Please take the time to read the information presented in the "Settings" section about the purposes of processing, storage and storage of personal data, the ability to update and delete this data, as well as the conditions and requirements for providing it to third parties.

Settings